Type SE36 – In-Line Flow Transmitter for Pipe Sizes to 2"

Ordering Chart
Specifications Voltage supply Output Electrical connection UL Approval Item no.
without display with display
2 outputs 14-36 V DC 1 x transistor + 1 x 4-20 mA
(2-wire)
5-pin M12
male fixed connector
No 560 880 561 880
UL Recognized Component Mark for Canada and US
Recognized
560 883 561 883
3 outputs 14-36 V DC 2 x transistors + 1 x 4-20 mA
(2-wire)
5-pin M12
male fixed connector
No 560 881 561 881
UL Recognized Component Mark for Canada and US
Recognized
560 884 561 884

Unique bayonet style flow meter constructed from an SE36 sensor and any of the S030 fittings. This two-wire 4-20 mA INLINE flow meter is manufactured to provide true, reliable flow for neutral, solid free liquids. A backlit removable display makes the system adds more value as it can program multiple transmitters.
Technical Data
Electronic module
Housing material Stainless steel, PPS, PC
Display Removable dot matrix 128 x 64 with backlight
Ambient temperature 32 °F - 140 °F
Voltage supply 14...36 VDC for 2-wire models
Electrical protection Short circuit protection
Reversed polarity of DC protected
Electrical connections M12
Outputs 4 ... 20 mA for flow rate
Transistor output NPN and PNP, 700 mA
Output load max. < 1100 Ω at 36 V
< 610 Ω at 24 V
< 180 Ω at 14 V
Ingress protection IP65 and 67, NEMA4X
Approvals UL Recognized, CSA through cURus, CE
Integrated sensor and fitting module
Size range 1/2" to 2" with bayonet fitting
Measuring ranges 1 to 33 fps
Measuring error (teach in) ≤ ± 1% o.FS (at 33fps)
Measuring error (Std. k-factor) ≤ ±(0.5% o.FS + 2.5% o.R)
Linearity ≤ ± 0.5% o.FS (at 33fps)
Repeatability 0.4% o.R.
Fitting materials PVC, PVDF, PP, Brass, Stainless, Stainless HT
Paddle wheel PVDF
Axis and bearing Ceramic
O-rings FKM
Max. fluid temperature 212 °F (metal), 122 °F (PVC)
Ambient temperature range 0 to 140 °F
Max. fluid pressure 232 PSI (metal), 145 PSI (PVC)
UL Recognized Component Mark for Canada and US
Options
  • Hygienic clamp and ASME weld end connections
  • ANSI flange connection
  • PVDF and PP fittings
  • Low flow fittings down to 6 mm
  • High flow fittings (8036) to 16"
  • Various sealing materials
  • Individual calibration certificate
  • Pre-wired cordsets and M12 connectors and cables
  • Display unit only (item number 559 168)
Envelope Dimensions [inch] (see datasheet for details)
Type SE36 Envelope Dimensions
A B C
3.82 2.56 5.16

Contact Us | Terms and Conditions | Privacy Policy